DuraVent Direct Vent Vertical Installation Kit

Product Images

DuraVent Direct Vent Vertical Installation Kit

DuraVent Direct Vent Vertical Installation Kit

DuraVent Direct Vent Vertical Installation Kit

DuraVent Direct Vent Vertical Installation Kit

DuraVent Direct Vent Vertical Installation Kit

DuraVent Direct Vent Vertical Installation Kit

Description:
The DuraVent Direct Vent Pro Vertical Installation Kit comes with the ceiling support box, the finish cover plate, the roof...

The DuraVent Direct Vent Pro Vertical Installation Kit comes with the ceiling support box, the finish cover plate, the roof flashing and the vertical high wind chimney cap. This provides all the base parts for a normal vertical venting installation.

As low as$441.99

Product Details:

The DuraVent Direct Vent Pro Vertical Installation Kit provides all the base parts necessary to properly vent the DuraVent direct vent pro pipe through a flat or vaulted ceiling and through the roof. The vertical installation kit is available in both the 4" inner 6 5/8" outer and the 5" inner and 8" outer pipes.

The vertical installation kit comes with the ceiling support box, vertical high wind chimney cap, the cover plate, storm collar and your choice of roof flashing for either a shingle or metal roof. The attic insulation shield is optional for installation where the pipe is required to pass through an attic space. Optional attic insulation shield is available for installation where the pipe is going through an attic space.

This kit is only compatible with DuraVent Direct Vent Pro pipe and components.

Specifications:

Base Kit Included Component Details

Ceiling Support

The DuraVent Direct Vent Pro Cathedral / Flat Ceiling Support will support the weight of the pipe for vertical venting applications. The support box comes with a support clamp, support box, and trim for around the box. The support box measures 10.625" x 10.625" and is 14" in length. Painted high temp black to match the black piping.

Vertical High Wind Chimney Cap

The DuraVent Direct Vent Pro Vertical High Wind Termination Cap is used as a termination cap for vertical venting through the roof. The high wind design will prevent any wind driven downdrafts. Check with your appliance manufacturer's installation instruction for the minimum height the cap needs to be above the roof.

Cover Plate

DuraVent Direct Vent Pro Ceiling Support / Wall Thimble Cover Plate is used as a decorative cover plate for a horizontal venting application to cover the wall thimble. It can also be used for flat ceilings as a trim collar. The cover comes with an insulated ring to reduce any infiltration through the ceiling or wall. The cover plate measures 13" x 13" and extends into the room 2". The black finish will match the black piping.

Roof Flashing

Shingle Roof Flashing

The DuraVent Direct Vent Pro Adjustable Roof Flashing is used to waterproof the roof penetration for vertical venting. The Adjustable Flashing is available for low pitch roofs ranging from 0/12 thru 06/12 roof pitch and also steep pitch roof ranging from 07/12 thru 12/12 roof pitch. The flashing is fabricated from galvalume steel. The storm collar is included.

Metal Roof Flashing

The DuraVent Direct Vent Pro Dead Soft Aluminum Roof Flashing is used to properly seal the vent pipe roof penetration through metal or tile roofs. The Dead Soft Flashing is able to conform to irregular shapes on the metal or tile roof. The Dead Soft Flashing is available in 0/12 thru 6/12 roof pitches and 7/12 thru 12/12 roof pitches. Storm collar is included.

Optional Component Details

Attic Insulation Shield

The DuraVent Direct Vent Pro Attic Insulation Shield is required for any vertical venting when the chimney pipe is passing through an attic space. The Attic Insulation Shield will prevent any insulation or debris from accumulating around the vent pipe. The Attic Insulation Shield will provide 1" clearance to combustible material. Includes the base plate, extension tube, and storm collar. The shield is able to adjust from 11" to 20" tall depending on the amount of insulation in the attic space. If the attic space is too low to accommodate the Attic Insulation Shield, the vent pipe must be enclosed in a chase.

Reviews:

Frequently Bought Together:

DIY Center

(AKA ‘The Rockford Files’)

From video tutorials to product walkthroughs, we have a variety of DIY resources just for you! Click the button below to view our entire library.

START LEARNING

Need Help?

We are here to answer all of your questions

1-866-708-2446

OR

CONTACT US

Our 316Ti flexible chimney liner and chimney liner components have passed the rigorous testing at the Underwriters Laboratories with best in class status and are UL Listed. So if you are looking for UL listed chimney liner sold directly to homeowners, then look no further than Rockford Chimney

Customer Testimonials

Back in July you gave me excellent advice re. sizing/purchasing a flue liner for the chimney associated with my wood stove. I'd like to thank you once agai... More

—AE Northfield, MN

A few weeks ago I ordered a chimney liner system for my fireplace insert. Your salesman recommended the liner system plus the insulating blanket. I just wa... More

—AH Happy customer

Just got around to installing my new smooth flexible liner and deluxe terra cotta cap (wow). The quality of your product is second to none. Very pleased an... More

—B.B. from Massachusetts

Thanks so much for the great tech service from Dennis, very knowledgable, friendly and proffessional.Your website is the best, beats your competition by fa... More

—Bill in Knoxville

Sue and Dennis, I received the final part of my order yesterday (the chimney cap that actually fits over the chimney chase). It looks wonderfu... More

—CC, VA

Hello, I was shopping for an fireplace insert and called RCS to ask why they were so much cheaper than my local guy, the reply was " we sell thousand of th... More

—Chris, PA.